Blum catalogue and technical manual

521 Runner systems 〉 SERVO-DRIVE for MOVENTO | TANDEM 〉 Applications Catalogue 2022/2023 • KA-150 Cabinet with inset fronts Planning Drilling distances – base | cross bar Drawer height SKH (mm) X (mm) Y (mm) ≥ 79 NL + FD + 18 NL + FD + 34 FD Front thickness NL Nominal length X Drilling position Y Min. space requirement Runner systems Drawer height SKH (mm) Internal cabinet width LW (mm) 224–234 235–388 389–428 ≥ 429 Z (mm) Lever exten- sion Z (mm) Lever exten- sion Z (mm) Lever exten- sion Z (mm) Lever exten- sion MOVENTO ≥ 79 – – 164 ● 164 ● LW / 2 ● TANDEM ≥ 79 164 – 164 ● LW / 2 ● LW / 2 ● LW Internal cabinet width ● Required Z Dimension of engagement – Not possible Lever extension Space requirement and safety distance – power supply unit housing Base fixing Panel fixing Attention Maintain a 30 mm safety distance from the bottom edge (base fixing) and/or front edge (panel fixing) and side edges of the power supply unit housing to the neighbouring elements! Air must be able to circulate, otherwise the SERVO-DRIVE power supply unit could overheat! Reference pages Overview 493 MOVENTO 416 TANDEM 446 Accessories 524 E-SERVICES and assembly devices 590 Machine directive 701 More technical details 698 Assembly, removal and adjustment Short URL www.blum.com/a450 Runner systems