Blum catalogue and technical manual_en

Z X 192 36.5 T 322 262 93 153 R23 75 275 135 75 215 75 45 377 3 〉 Box systems 〉 SERVO-DRIVE for LEGRABOX | MERIVOBOX | TANDEMBOX 〉 Applications Catalogue 2027/2028 Standard cabinet Planning – cross bar construction vertical Drilling distances – base | cross bar Back X (mm) T (mm) Chipboard back NL + 19 NL + 34 Steel back NL + 2 NL + 17 NL Nominal length X Drilling position T Position – front edge–cross member Z Dimension of engagement Box systems Back Back height Internal cabinet width LW (mm) 242–266 267–286 287–316 Z (mm) Lever extension Trigger guidance Z (mm) Lever extension Trigger guidance Lever cap Z (mm) Lever extension Trigger guidance LEGRABOX ¹ Chipboard back N – – – 184 ● – – 184 ● – M | K | C | F – – – 184 ● – – 184 ● – Steel back N – – – – – – – – – – M | K | C | F – – – 184 ✖ – ● 184 ● – MERIVOBOX Chipboard back N – – – 174 ✖ – – 174 ● – M | K | E – – – 174 ✖ – – 174 ● – Steel back N – – – – – – – – – – M | K | E – – – 174 ● – – 174 ● – TANDEMBOX Chipboard back N 179 ✖ ● 179 ● ● – 179 ● ● M | K | B | C | D 179 ✖ ● 179 ● ● – 179 ● ● Steel back N – – – – – – – 190 ✖ – M | K | B | C | D – – – 179 ✖ – – 179 ● – Box systems Back Back height Internal cabinet width LW (mm) 317–386 ≥ 387 Z (mm) Lever extension Trigger guidance Z (mm) Lever extension Trigger guidance LEGRABOX ¹ Chipboard back N 184 ● – LW / 2 ● – M | K | C | F 184 ● – LW / 2 ● – Steel back N – – – – – – M | K | C | F 184 ● – LW / 2 ● – MERIVOBOX Chipboard back N 174 ● – LW / 2 ● – M | K | E 174 ● – LW / 2 ● – Steel back N – – – – – – M | K | E 174 ● – LW / 2 ● – TANDEMBOX Chipboard back N 179 ● ○ LW / 2 ● ○ M | K | B | C | D 179 ● ○ LW / 2 ● ○ Steel back N 190 ● – LW / 2 ● – M | K | B | C | D 179 ● – LW / 2 ● – LW Internal cabinet width ○ Not required Z Dimension of engagement – Not possible ● Required ✖ Remove ¹ When using SERVO-DRIVE in combination with AMPEROS AC, the minimum internal cabinet width LW is 562 mm Lever extension Lever cap Trigger guidance Space requirement and safety distance – power supply unit housing Mounting on the ground Wall fixing Attention Maintain a 30 mm safety distance from the bottom edge (base fixing) and/or front edge (wall fixing) and side edges of the power supply unit housing to the neighbouring elements! Air must be able to circulate, otherwise the SERVO-DRIVE power supply unit could overheat! Reference pages Overview 371 LEGRABOX 192 MERIVOBOX 250 TANDEMBOX 294 AMPEROS AC for LEGRABOX 588 Order information 372 Planning – cross bar construction horizontal 374 Accessories 400 Blum services 616 Machine directive 727 More technical details 724 Assembly, removal and adjustment Short URL www.blum.com/a380 3

RkJQdWJsaXNoZXIy